Shahdara, New Delhi, Delhi
GST No. 07ANFPA0867R1ZN
Call 08046044567 81% Response Rate
Minimum Order Quantity: 10 Piece
Product Brochure
Brand | Airatom |
Weight | 195 Gram |
Model Name/Number | AA-GAS-79 |
Material | ABS Plastic |
Is It Portable | Portable |
Dimensions | 15 x 8.5 x 4 cm |
Country of Origin | Made in India |
View Complete details
Minimum Order Quantity: 2 Piece
Operating Voltage | 24V |
Output Current ( in mA) | 4-20 mA |
Usage/ Application | Office, Commercial Building, etc. |
Product Type | CO2 Sensor |
MountingType | Wall Mounted |
Output Type | Analog |
Packaging Type | Hard Card Box |
We are engaged in offering Analog Output Co2 Sensor to our clients. Our range of all products is widely appreciated by our clients.
CO2 concentration - 400-5000PPM
Out put signal - 4-20ma analog output
Operating voltage - 24v DC power supply.
Precision - +-40PPM
View Complete details
Minimum Order Quantity: 2 Piece
No. of Input Channel | 4 |
Target gases | co2 |
Measuring Range | 400-5000ppm |
Brand | AIRATOM |
Model Name/Number | AA-co2-analog |
Power | 24V DC |
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Target gases | CO2 |
Measuring Range | 9Mpa |
Brand | airatom |
Output Current ( in mA) | N/A |
Warranty | N/A |
Usage/ Application | Cold drinks, beer bottles |
CO2 sensors are devices that measure the concentration of carbon dioxide in the air. They are used in various settings like homes, offices, industries, and even in vehicles to monitor indoor air quality, ensure safety, and regulate ventilation systems. These sensors work by detecting the presence of CO2 through various technologies such as non-dispersive infrared (NDIR) sensors, metal oxide semiconductor sensors, and electrochemical sensors.
Additional Information:
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Target gases | co2 |
Measuring Range | 0-10000 |
Operating Voltage | 24V |
Brand | esense |
Output Current ( in mA) | 4-20 |
Warranty | 1 |
Usage/ Application | co2 measurement |
Detection Principle | NDIR |
Response Time | <3sec |
Expected Operating Life | >15 years |
View Complete details
Minimum Order Quantity: 2 Piece
Detector Type | Fixed Single Gas |
Name of Gases Detected | co2 |
Model | ds-co2-20 |
Measuring Range | 0-5000 |
Accuracy | +-30 |
View Complete details
Minimum Order Quantity: 1 Piece
Product Brochure
Target gases | CO2, carbon dioxide |
Measuring Range | 0-10000 |
Operating Voltage | 12V |
Brand | SenseAir |
Warranty | 1 year |
Usage/ Application | RS485 modbus protocal |
Detection Principle | NDIR with ABC algorithm |
Response Time | 6 minutes |
Modbus Output | RS485 |
Preheat Duration | 60 seconds |
co2 | sense air |
Additional Information:
View Complete details
Product Brochure
Display | LCD |
Power Supply | Battery |
Measuring Range | 0-5000PPM |
Weight | 500g |
Brand | Rotronic |
Calibration | Automatic |
Battery Life | 8hr |
Data Logger | Yes |
Features | Co2 , Temperature + Humidity |
Operating Temperature | -10 to +60 |
Portable | Yes |
Power Source | DC and Power Adaptor |
Humidity sensor | ROTRONIC HYGROMER® IN-1 |
---|---|
Temperature sensor | Thermistor |
Long-term stability | < 1.5 %RH per year |
Measuring range | 0…5000 ppm, 0.1...99.95 %RH, -20...60 °C |
Accuracy at 23 ±5 °C | ±30 ppm ±5 % of the measured value, ±2 %rF (10...90 %rF), others ± 5 %rF, ±0,3 K |
Response time t 63 | <30 s, without filter |
Alarm functions | Adjustable for CO2 measurement |
Dimensions | 76,7 x 41,8 x 233,9 mm |
IP protection rating | IP30 |
Weight | 290 g |
Housing | ABS |
Parameters shown | CO2, relative humidity and temperature |
Calculations | Dew point, wet bulb temperature |
Clock | Real time clock |
Current consumption | 40 mA (typical) |
CE / EMC conform | 2004/108/EC |
Power supply | 4 x AA batteries / optional AC adapter AC1214 |
Battery lifetime | 50 h |
Measured value memory | 18,000 values with time stamp, automatic recording (%RH / °C / ppm), 99 single values with time stamp, manual recording, (%RH / °C / DP / Tw / ppm) |
Measurement principle | Non dispersive infrared (NDIR) with automatic baseline correction (ABC) |
Response time | <10 sec @ 30 cc/min. flow, <3 min diffusion time |
Adjustment points | 0, 400 ppm and 35, 80 %RH |
Pressure dependence | +1.6 % reading per kPa |
Zero drift | <10 ppm/year |
Maintenance | No maintenance (standard indoor application) |
Warm-up time | <1 min. |
View Complete details